Black Garlic fermentation box instructions

Structural characteristics of the device
1, the device according to split structure design, studio overall welding molding, cabinet made of the overall structure, square steel base with GB spray made of the overall framework, in the studio chamber body part and the chamber door and power distribution cabinets, etc. parts of the use of stiffeners to ensure strong and stable overall structure of the device.
2, the device’s electronic control system installed in the cabinet, the cabinet rear installed in the test chamber to form a whole. Heater and circulation pump mounted on the chamber body at the top of the left and right sides of a special duct to ensure that the test chamber temperature uniformity and stability.
3, the equipment inside and outside the box is high quality 304 brushed stainless steel plate (thickness 1.0mm), and use the most advanced processing equipment and processing molding, beautiful, smooth, atmospheric, arc design, smooth lines and natural, reasonable design, durable.
4, cabinet insulation insulation using rigid PU foam and silicate cotton, silicate cotton than similar fiberglass surface with a high temperature, low heat transfer coefficient, and other characteristics, insulation thickness of 100mm, to ensure that the test chamber temperature is not transmitted to the outside of the device, so that a more accurate test test temperature.
5, the device meets the requirements under the premise of all aspects of performance are based on a more stable and easy to control with practicality. And
And the device has easy installation, simple operation, with almost no routine maintenance.
6, the chamber with double door structure, openings Dimensions: 2.2 (W) * 2.3 (height) m, in the center of the chamber door installed two observation windows for the observation of changes in the sample chamber. Three-layer hollow glass viewing window, external double glue chip conductive film, transparent, heat insulation, easy to produce steam condensation, etc., with a high-quality lighting can be assisted viewing in low light test box test case . Activities at the door with ramp for easy access to raw materials carts laboratory.
7, the inner loop system using at least six (three on each side) High resistance to high temperature axis motor with high temperature resistance of aluminum multi-blade impeller, the forced convection vertical diffusion cycle, the laboratory has a separate a special circulation duct, so that uniform temperature and humidity inside the laboratory and kept constant.
8, the chamber door and the box using double sheets of high resistance, high temperature resistance silicone seal to ensure a closed test. Doors are made of stainless steel inside and outside the board material, beautiful, durable, no reaction door handles for easier operation, durable, easy to damage.
9, the device control part of the design in the rear of the device, the distribution of temperature controller, control switch, convenient operation, simple, easy to
Maintenance. Temperature and time can be programmed to control multi-stage, temperature and time can be set and automatically executed.
Control method and characteristics
Balanced temperature control system (BTHC) + specially designed fan forced air circulation system to PID control the SSR, the Department of
The system plus heat equals heat loss, so the use of long-term stability.
Equipment technical parameters
In the absence of the test load, the case without shelf stable performance was measured after 2 hours. In addition, with regard to the temperature rise and fall time is air-cooled at room temperature +25 ℃, no-load performance
1, Temperature range: RT +10 ℃ – 100 ℃.
2, Temperature fluctuation: ± 0.5 ℃.
3, heating time :2.0-3 .0 ℃ / min
4, humidity :45-95% RH (humidity-controlled temperature setting must be greater than 60 ℃, because the machine does not dehumidification function, it can only be compared to the surrounding environment of high humidity and high humidity 20RH more than manageable.)
5, Humidity fluctuation: ± 5RH%.
※ temperature change rate is the rate of change of air temperature, rate of temperature change rather than the product.

 

 